There may be a number of reasons why your heater pump is displaying an error code. The following is a list of error codes, the reason behind them and how they can be solved.
The EO2 error can affect all AirJet™ and HydroJet™ Lay-Z-Spa hot tubs. There are a number of causes which can be fixed quickly and easily.Cause 1: Dirty filt. Whether you own one or hire a hot tub, this guide will hopefully get you back to enjoying your hot tub in the shortest time possible. Welcome To Our Website! Check out our range of products available for hire!
Select Your Error Code:
E01
← swipe →
Description | Cause | Solution |
---|---|---|
Sensor Error | The water flow sensors’ flags didn’t come back into the correct position. | Unplug the pump unit, lightly strike the side of it and then plug it back in. If the unit does not respond, try rolling the pump unit on its side in order to shift the sensor placement. |
Water Flow Error | Electrical issue. Can occur when the spa is not plugged into a mains socket. May also be an issue with the RCD socket. | Plug the pump unit directly into a mains socket and not into an extension lead. |
Debris Build Up | Issue with water flora sensors due to debris build up. | Please follow the backwash procedure in the video here |
E02
← swipe →
Description | Cause | Solution |
---|---|---|
Water Flow Error | The stopper caps are still inside the spa. | Remove the black stopper caps from the inside of the liner before heating, filtering or running the bubbles on the spa. If you are unsure how to remove them, please refer to the assembly section within the Lay-Z-Spa owners manual. |
Filter cartridges are dirty | Remove the filter cartridge from the filter housing and check it is clean. Please make sure the new filter is clean and dry before you install it. | |
Filter housing is restricting flow | Remove the filter housing from the liner and check the black membrane inside. These should lie flat inside the housing. If they are ok, continue to run the spa without the filter cartridge attached and see if the error code persists. | |
Ensure that the debris screens are clear of debris. | ||
Pipes within the liner are kinked or bent. | Disconnect the pump and check the pipes inside the liner. You can manipulate these with warm water to return them to the correct shape. | |
Washers perished inside pump couplings | Disconnect the pump from the liner. Check the condition of washers inside the couplings on the pump. We would suggest backwashing the pump to clear any debris. If the washers are perished you can purchase spares from the Lay-Z-Spa website here | |
Water flow sensors not working | If the above troubleshooting has not resolved the problem, the water flow sensors may not be working. Please contact us for more help with this |
E02 Error Code Troubleshooting download
E03
← swipe →
Description | Cause | Solution |
---|---|---|
Temperature too low | The pump will only operate when the ambient temperature is above 4°C. We would suggest disconnecting the pump and moving it to a warmer place. You will need to do the thermal reset procedure before continuing use. | The pump will only operate when the ambient temperature is above 4ºC. |
The pump thermometer is broken. | If your pump is displaying this message and the ambient temperature is above 4ºC. Please contact us for more help. |
E04
← swipe →
Description | Cause | Solution |
---|---|---|
Temperature too high | The pump unit has overheated. | Place the stoppers caps inside the spa and disconnect the pump unit. Allow time for the pump unit to cool down before connecting again. |
The water temperature is over 50ºC (122ºF). | The Lay-Z-Spa is not designed to operate with water temperatures exceeding 40ºC (104ºF). Unplug the pump and plug it back in once the water temperature has reached 38ºC (100ºF) or lower. IMPORTANT: Before you restart the pump, press the reset button. | |
The thermostat needs resetting. |
|
E05
← swipe →
Description | Cause | Solution |
---|---|---|
Temperature too high | The thermostat is broken. | If the troubleshooting has been completed without success, please contact usfor more help with this |
Pump needs to be reset. |
| |
Pump unit needs to be cleaned | Try the back wash procedure. | |
Not enough power to the pump. | Ensure the pump unit is plugged into a mains socket and not an extension lead. |
E06
← swipe →
Description | Cause | Solution |
---|---|---|
Electrical Fault | The power port has experienced a temporary current variation. | Unplug the pump and hen plug it back in. Please ensure the pump unit is plugged into a mains socket and not an extension lead. |
E07
← swipe →
Description | Cause | Solution |
---|---|---|
Electrical Fault | The pump has read an electrical error. | Try the reset procedure detailed in the troubleshooting document. If the troubleshooting has been completed without success, please contact us for more help. |
E08
← swipe →
Description | Cause | Solution |
---|---|---|
The thermostat needs resetting. |
|
E09
← swipe →
Description | Cause | Solution |
---|---|---|
Fuse Failure. | Internal fuse failure or has become disconnected within the pump. |
|
E10
← swipe →
Description | Cause | Solution |
---|---|---|
High salt alarm. | Alarm where too much salt has been added to the spa or a large amount of water has evaporated. |
|
E11
← swipe →
Description | Cause | Solution |
---|---|---|
Low salt alarm. | Alarm for low salt levels within the spa. This means the spa requires further salt to be added. |
|
E12
← swipe →
Description | Cause | Solution |
---|---|---|
Water Leakage. | Error code for an issue with water leaking within the body of the pump. |
|
E13
Komatsu Error Code E03
← swipe →
Description | Cause | Solution |
---|---|---|
Signal within the pump. | Error code for issue where the electrical signal within the pump body between the control panel and power board has become disconnected. |
|
GCF
← swipe →
Description | Cause | Solution |
---|---|---|
Not grounded/earthed correctly | An issue with your power supply | Remove any extension leads, we do not recommend the pump is run on one of these. Also try the pump in an alternative socket. If the issue persists, please contact us for further advice. |
Backwash Procedure
Attach the stopper caps to the inside of the liner and then remove the Lay-Z-Spa pump unit from the liner (you can do this by unscrewing the 3 couplings ‘A, B and C’).
Using a hosepipe, flush water backwards through the pump. Water should go through pipe ‘B’ and come out of pipe ‘C’.
After a few minutes, flush the water in the opposite direction for about 2 minutes (through pipe ‘C’ and out of pipe ‘B’).
If you have a Hydro Jet Lay-Z-Spa, unfortunately, the backwash procedure will be a little tricky. These are not constructed like the other models of the Lay-Z-Spa. please contact us
There may be a number of reasons why your heater pump is displaying an error code. The following is a list of error codes, the reason behind them and how they can be solved.
Select Your Error Code:
E01
← swipe →
Description | Cause | Solution |
---|---|---|
Sensor Error | The water flow sensors’ flags didn’t come back into the correct position. | Unplug the pump unit, lightly strike the side of it and then plug it back in. |
Water Flow Error | Electrical issue. Can occur when the spa is not plugged into a mains socket. May also be an issue with the RCD socket. | Plug the pump unit directly into a mains socket and not into an extension lead. |
E02
← swipe →
Description | Cause | Solution |
---|---|---|
Water Flow Error | The stopper caps are still inside the spa. | Remove the stopper caps before heating your Lay-Z-Spa. If you’re unsure how to remove them, refer to the assembly section within the Lay Z Spa Owner’s Manual. |
Water Flow Error | Filter cartridges are dirty | Remove the filter cartridges from the pump and press the filter or heat button. If no alarm appears, you will need to clean or replace the filter cartridges. |
Water Flow Error | Filter housing is restricting flow | Remove the filter cartridges from the pump and press the filter or heat button. If no alarm appears, you will need to clean or replace the filter cartridges. |
Water Flow Error | Debris screens are blocked. | Ensure that the debris screens are clear of debris. |
Pipes within the liner are kinked or bent. | Using your hands, check the condition of the pipes within the liner. | |
Water Flow Error | Water flow sensors not working | If the above troubleshooting has not resolved the problem, the water flow sensors may not be working. Please contact us for more help with this |
E02 Error Code Troubleshooting download
Evaluasi media pembelajaran pdf. Metode pengumpulan data yang digunakan yaitu wawancara, observasi dan dokumentasi. Analisis data yang digunakan yaitu reduksi data, display data dan verifikasi data. Keabsahan data penelitian menggunakan tringulasi sumber.
E03
← swipe →
Description | Cause | Solution |
---|---|---|
Temperature too low | Normally caused when the Lay Z Spa pump has been used in temperatures below 4ºC. | The pump will only operate when the ambient temperature is above 4ºC. |
Temperature too low | The pump thermometer is broken. | If your pump is displaying this message and the ambient temperature is above 4ºC. Please contact us for more help. |
E04
← swipe →
Description | Cause | Solution |
---|---|---|
Temperature too high | The pump unit has overheated. | Place the stopper caps inside the spa, disconnect the pump unit, and bring the pump unit inside to cool down. |
Temperature too high | The water temperature is over 50ºC (122ºF). | The Lay-Z-Spa is not designed to operate with water temperatures exceeding 40ºC (104ºF). Unplug the pump and plug it back in once the water temperature has reached 38ºC (100ºF) or lower. IMPORTANT: Before you restart the pump, press the reset button. |
Temperature too high | The thermostat needs resetting. |
|
E05
← swipe →
Description | Cause | Solution |
---|---|---|
Temperature too high | The thermostat is broken. | If the troubleshooting has been completed without success, please contact usfor more help with this |
Pump needs to be reset. |
| |
Pump unit needs to be cleaned | Try the back wash procedure. | |
Not enough power to the pump. | Ensure the pump unit is plugged into a mains socket and not an extension lead. | |
Pump may be faulty. | If the troubleshooting has been completed without success, please contact usfor more help with this |
E06
← swipe →
Description | Cause | Solution |
---|---|---|
The power port has experienced a temporary current variation. | Unplug the pump and then plug the pump back in. | |
Pump may be faulty. | If the troubleshooting has been completed without success, please contact usfor more help with this |
E07
← swipe →
Description | Cause | Solution |
---|---|---|
Please contact us regarding this problem. | If the troubleshooting has been completed without success, please contact usfor more help with this |
E08
← swipe →
Description | Cause | Solution |
---|---|---|
The thermostat needs resetting. |
|
E09
Whirlpool Duet E03 Error Code
← swipe →
Description | Cause | Solution |
---|---|---|
Fuse Failure. | Internal fuse failure or has become disconnected within the pump. |
|
E10
← swipe →
Description | Cause | Solution |
---|---|---|
High salt alarm. | Alarm where too much salt has been added to the spa or a large amount of water has evaporated. |
|
E11
← swipe →
Description | Cause | Solution |
---|---|---|
Low salt alarm. | Alarm for low salt levels within the spa. This means the spa requires further salt to be added. |
|
E12
← swipe →
Description | Cause | Solution |
---|---|---|
Water Leakage. | Error code for an issue with water leaking within the body of the pump. |
|
E13
← swipe →
Description | Cause | Solution |
---|---|---|
Signal within the pump. | Error code for issue where the electrical signal within the pump body between the control panel and power board has become disconnected. |
|
GCF
← swipe →
Coleman Hot Tub Error Code E03
Description | Cause | Solution |
---|---|---|
Not grounded/earthed correctly. | An issue with your extension lead or power supply. | Remove extension lead or get a qualified electrician to check your socket & power supply. If this does not resolve the issue, please contact us. |
Backwash Procedure
Attach the stopper caps to the inside of the liner and then remove the Lay-Z-Spa pump unit from the liner (you can do this by unscrewing the 3 couplings ‘A, B and C’).
Using a hosepipe, flush water backwards through the pump. Water should go through pipe ‘B’ and come out of pipe ‘C’.
Bosch Dryer Error Code E03
After a few minutes, flush the water in the opposite direction for about 2 minutes (through pipe ‘C’ and out of pipe ‘B’).
E03 Error Code Whirlpool
If you have a Hydro Jet Lay-Z-Spa, unfortunately, the backwash procedure will be a little tricky. These are not constructed like the other models of the Lay-Z-Spa. please contact us